R290 monoblocks
Propane, a natural refrigerant, with a reduced charge, for small and medium-sized cold rooms.
It straddles the cold room wall (over-the-wall mounting): the evaporator sits inside and the condensing unit outside, in a single unit with a sealed circuit and the controls on the unit itself. For chilled and frozen storage, in R290, R455A and CO₂.
65 models at 50 Hz · Panels from 60 to 160 mm, and up to 200 mm on freezer models · Air-cooled or water-cooled
The option when the unit has to sit over the top edge of a cold room wall, without taking up ceiling or floor space. It arrives ready to run: there are no refrigerant lines to run on site.
Equipment as listed in the R290 and R455A catalogues. CO₂ Laika units have a semi-hermetic compressor, an electronic expansion valve and a water-cooled plate condenser.
The 65 Laika 50 Hz models, with the cooling capacity and guide room volume given in the CIBIN catalogue. Choose the refrigerant and filter by type of cold room.
Propane, a natural refrigerant (GWP 3), with a maximum of 150 g per circuit. 24 models.
Swipe the table to see all the columns →
| Model | Cold room | Condenser | Power supply | Capacity W | Guide room volume m³ | Sound pressure dB(A) at 10 m | Dimensions W × H × D mm | Quote |
|---|---|---|---|---|---|---|---|---|
| Laika 05123N | Chiller | Air-cooled | 230/1/50 | 736 | 5.5 | 52 | 320 × 650 × 870 | Request price |
| Laika 08125N | Chiller | Air-cooled | 230/1/50 | 1076 | 9.5 | 52 | 450 × 730 × 905 | Request price |
| Laika 12125N | Chiller | Air-cooled | 230/1/50 | 1364 | 13 | 52 | 450 × 730 × 905 | Request price |
| Laika 14125N | Chiller | Air-cooled | 230/1/50 | 1523 | 15.5 | 52 | 450 × 730 × 905 | Request price |
| Laika 25130N | Chiller | Air-cooled | 230/1/50 | 2363 | 26.5 | 53 | 645 × 860 × 940 | Request price |
| Laika 38225N | Chiller | Air-cooled | 230/1/50 | 3054 | 36.5 | 55 | 800 × 860 × 925 | Request price |
| Laika 67325N | Chiller | Air-cooled | 400/3/50 | 4652 | 60 | 57 | 1150 × 860 × 925 | Request price |
| Laika 05123B | Freezer | Air-cooled | 230/1/50 | 576 | 4.5 | 50 | 320 × 650 × 910 | Request price |
| Laika 08125B | Freezer | Air-cooled | 230/1/50 | 876 | 8.5 | 52 | 450 × 730 × 945 | Request price |
| Laika 11125B | Freezer | Air-cooled | 230/1/50 | 1037 | 11 | 52 | 450 × 730 × 945 | Request price |
| Laika 29225B | Freezer | Air-cooled | 230/1/50 | 2077 | 29 | 55 | 800 × 860 × 965 | Request price |
| Laika 50325B | Freezer | Air-cooled | 400/3/50 | 3215 | 52 | 57 | 1150 × 860 × 965 | Request price |
| Laika 05123N-W | Chiller | Water-cooled | 230/1/50 | 631 | 4.2 | — | 320 × 650 × 870 | Request price |
| Laika 08125N-W | Chiller | Water-cooled | 230/1/50 | 897 | 7.1 | — | 450 × 730 × 905 | Request price |
| Laika 12125N-W | Chiller | Water-cooled | 230/1/50 | 1164 | 10.1 | — | 450 × 730 × 905 | Request price |
| Laika 14125N-W | Chiller | Water-cooled | 230/1/50 | 1293 | 11.6 | — | 450 × 730 × 905 | Request price |
| Laika 25130N-W | Chiller | Water-cooled | 230/1/50 | 1969 | 20.1 | — | 645 × 860 × 940 | Request price |
| Laika 38225N-W | Chiller | Water-cooled | 230/1/50 | 3661 | 42.8 | — | 800 × 860 × 925 | Request price |
| Laika 67325N-W | Chiller | Water-cooled | 400/3/50 | 3939 | 46.7 | — | 1150 × 860 × 925 | Request price |
| Laika 05123B-W | Freezer | Water-cooled | 230/1/50 | 488 | 3.3 | — | 320 × 650 × 910 | Request price |
| Laika 08125B-W | Freezer | Water-cooled | 230/1/50 | 706 | 6 | — | 450 × 730 × 945 | Request price |
| Laika 11125B-W | Freezer | Water-cooled | 230/1/50 | 861 | 8.1 | — | 450 × 730 × 945 | Request price |
| Laika 29225B-W | Freezer | Water-cooled | 230/1/50 | 1721 | 22.1 | — | 800 × 860 × 965 | Request price |
| Laika 50325B-W | Freezer | Water-cooled | 400/3/50 | 2661 | 40.2 | — | 1150 × 860 × 965 | Request price |
No models match those filters for this refrigerant.
New-generation A2L refrigerant (GWP 146). 36 models, with three-phase versions (T).
Swipe the table to see all the columns →
| Model | Cold room | Condenser | Power supply | Capacity W | Guide room volume m³ | Sound pressure dB(A) at 10 m | Dimensions W × H × D mm | Quote |
|---|---|---|---|---|---|---|---|---|
| Laika 04123N | Chiller | Air-cooled | 230/1/50 | 673 | 5 | 50 | 320 × 650 × 870 | Request price |
| Laika 06125N | Chiller | Air-cooled | 230/1/50 | 1013 | 9 | 52 | 450 × 730 × 905 | Request price |
| Laika 07125N | Chiller | Air-cooled | 230/1/50 | 1263 | 12 | 52 | 450 × 730 × 905 | Request price |
| Laika 09125N | Chiller | Air-cooled | 230/1/50 | 1348 | 13 | 52 | 450 × 730 × 905 | Request price |
| Laika 18130N | Chiller | Air-cooled | 230/1/50 | 1732 | 18 | 53 | 645 × 860 × 940 | Request price |
| Laika 21130N | Chiller | Air-cooled | 230/1/50 | 1876 | 20 | 53 | 645 × 860 × 940 | Request price |
| Laika 24225N | Chiller | Air-cooled | 230/1/50 | 2348 | 26.5 | 55 | 800 × 860 × 925 | Request price |
| Laika 37325N | Chiller | Air-cooled | 230/1/50 | 3276 | 39.5 | 57 | 1150 × 860 × 925 | Request price |
| Laika 37325N(T) | Chiller | Air-cooled | 400/3/50 | 3371 | 41 | 57 | 1150 × 860 × 925 | Request price |
| Laika 42325N | Chiller | Air-cooled | 230/1/50 | 3585 | 44 | 57 | 1150 × 860 × 925 | Request price |
| Laika 42325N(T) | Chiller | Air-cooled | 400/3/50 | 3491 | 42.5 | 57 | 1150 × 860 × 925 | Request price |
| Laika 06125B | Freezer | Air-cooled | 230/1/50 | 704 | 6 | 52 | 450 × 730 × 945 | Request price |
| Laika 08125B | Freezer | Air-cooled | 230/1/50 | 917 | 9 | 52 | 450 × 730 × 945 | Request price |
| Laika 17130B | Freezer | Air-cooled | 230/1/50 | 1374 | 16.5 | 53 | 645 × 860 × 980 | Request price |
| Laika 17130B(T) | Freezer | Air-cooled | 400/3/50 | 1390 | 16.5 | 53 | 645 × 860 × 980 | Request price |
| Laika 23225B | Freezer | Air-cooled | 230/1/50 | 1808 | 24 | 55 | 800 × 860 × 965 | Request price |
| Laika 23225B(T) | Freezer | Air-cooled | 400/3/50 | 1770 | 23 | 55 | 800 × 860 × 965 | Request price |
| Laika 32325B(T) | Freezer | Air-cooled | 400/3/50 | 2358 | 34.5 | 57 | 1150 × 860 × 965 | Request price |
| Laika 04123N-W | Chiller | Water-cooled | 230/1/50 | 758 | 6 | — | 320 × 650 × 870 | Request price |
| Laika 06125N-W | Chiller | Water-cooled | 230/1/50 | 1107 | 10 | — | 450 × 730 × 905 | Request price |
| Laika 07125N-W | Chiller | Water-cooled | 230/1/50 | 1357 | 13 | — | 450 × 730 × 905 | Request price |
| Laika 09125N-W | Chiller | Water-cooled | 230/1/50 | 1494 | 15 | — | 450 × 730 × 905 | Request price |
| Laika 18130N-W | Chiller | Water-cooled | 230/1/50 | 1884 | 20 | — | 645 × 860 × 940 | Request price |
| Laika 21130N-W | Chiller | Water-cooled | 230/1/50 | 2140 | 23.5 | — | 645 × 860 × 940 | Request price |
| Laika 24225N-W | Chiller | Water-cooled | 230/1/50 | 2564 | 29.5 | — | 800 × 860 × 925 | Request price |
| Laika 37325N-W | Chiller | Water-cooled | 230/1/50 | 3582 | 44 | — | 1150 × 860 × 925 | Request price |
| Laika 37325N-W(T) | Chiller | Water-cooled | 400/3/50 | 3604 | 44 | — | 1150 × 860 × 925 | Request price |
| Laika 42325N-W | Chiller | Water-cooled | 230/1/50 | 3934 | 49 | — | 1150 × 860 × 925 | Request price |
| Laika 42325N-W(T) | Chiller | Water-cooled | 400/3/50 | 3753 | 46.5 | — | 1150 × 860 × 925 | Request price |
| Laika 06125B-W | Freezer | Water-cooled | 230/1/50 | 755 | 7 | — | 450 × 730 × 945 | Request price |
| Laika 08125B-W | Freezer | Water-cooled | 230/1/50 | 989 | 10 | — | 450 × 730 × 945 | Request price |
| Laika 17130B-W | Freezer | Water-cooled | 230/1/50 | 1552 | 19.5 | — | 645 × 860 × 980 | Request price |
| Laika 17130B-W(T) | Freezer | Water-cooled | 400/3/50 | 1559 | 19.5 | — | 645 × 860 × 980 | Request price |
| Laika 23225B-W | Freezer | Water-cooled | 230/1/50 | 1980 | 27 | — | 800 × 860 × 965 | Request price |
| Laika 23225B-W(T) | Freezer | Water-cooled | 400/3/50 | 1956 | 26.5 | — | 800 × 860 × 965 | Request price |
| Laika 32325B-W(T) | Freezer | Water-cooled | 400/3/50 | 2508 | 37.5 | — | 1150 × 860 × 965 | Request price |
No models match those filters for this refrigerant.
Subcritical cycle, water-cooled, with inlet water at 20 °C maximum. 5 three-phase models.
Swipe the table to see all the columns →
| Model | Cold room | Power supply | Capacity W | Guide room volume m³ | Dimensions W × H × D mm | Quote |
|---|---|---|---|---|---|---|
| Laika 26130N-SW | Chiller | 400/3/50 | 2432 | 26.1 | 645 × 865 × 930 | Request price |
| Laika 39225N-SW | Chiller | 400/3/50 | 3216 | 36.7 | 800 × 865 × 890 | Request price |
| Laika 60325N-SW | Chiller | 400/3/50 | 4342 | 52.4 | 1150 × 865 × 890 | Request price |
| Laika 26130B-SW | Freezer | 400/3/50 | 1896 | 25.3 | 645 × 865 × 930 | Request price |
| Laika 35225B-SW | Freezer | 400/3/50 | 2326 | 33.5 | 800 × 865 × 890 | Request price |
No models match those filters for this refrigerant.
Cooling capacity and guide room volume from the CIBIN catalogue, with the cold room at 0 °C for chiller and −20 °C for freezer models, and an ambient temperature of 32 °C. The volume is for a cube-shaped cold room insulated on all sides, with product entering at +15 °C (chiller) or −15 °C (freezer). Dimensions taken from the catalogue drawings, for guidance only.
For other temperatures, the catalogue gives the full table for each model. And for a calculation based on your actual conditions, tell us about your cold room.
The code sums up the unit size, the condenser fans and the type of cold room. It is explained in CIBIN's own catalogue.
In addition, (T) indicates a 400 V three-phase version, and SW the water-cooled subcritical-cycle CO₂ units. The same code may exist in Laika, Kuma and Norca with different capacities: when ordering a unit, always state the series and the refrigerant.
CIBIN's three monoblock catalogues, with the data sheet, drawing and capacity table for each model. Browse them here or download them, no registration needed.
According to the catalogue drawings, chiller models take panels from 60 to 160 mm and freezer models from 60 to 200 mm. If your panel is outside that range, look at Norca (through-wall) or Kuma (ceiling-mounted).
R290 is propane: a natural refrigerant, GWP 3 and class A3 (flammable), with a maximum of 150 g per circuit. R455A is an A2L blend, mildly flammable, with GWP 146. Both cover chilled and frozen storage, air-cooled or water-cooled.
CO₂ (GWP 1) is only made in water-cooled, three-phase versions, and runs at high pressure: it calls for a contractor trained in CO₂.
When the heat cannot be rejected into the air of the premises. The unit transfers it to a water circuit through a plate condenser; several units can share the same water loop, which is cooled by a dry cooler or put to use with heat pumps.
The maximum water inlet temperature is 48 °C for R290 and 20 °C for R455A and CO₂.
By the capacity at the actual cold room and ambient temperatures, not by the nominal capacity on the data sheet. The table above gives the capacity and guide volume at 32 °C ambient; the Laika R290 selector covers the other temperatures.
The volume is a guide only: it depends on the product, door openings and insulation. Tell us about your cold room and we'll tell you the model.
No. The catalogue specifies them for an ambient temperature of +16 to +43 °C and excludes cold rooms located outdoors, potentially explosive atmospheres and products that give off corrosive substances.
If the unit cannot straddle the wall, or you need more capacity. All CIBIN equipment.
Tell us the volume, the temperature and where the unit will go, and we'll tell you the model, price and lead time.