Ceiling-mounted monoblock · CIBIN

CIBIN Kuma monoblock

It is mounted on top of the cold room ceiling and the evaporator drops in through an opening: the walls stay clear. A single unit with a sealed circuit, operated from a remote control panel. For chilled and frozen storage, in R290, R455A and CO₂.

66 models at 50 Hz · The evaporator projects 130 to 160 mm below the ceiling · Air-cooled or water-cooled

CIBIN Kuma ceiling-mounted monoblock with its remote control panel
Kuma monoblock and its control panel · manufacturer's render

Kuma at a glance

The option when you do not want to take up wall or door space and the cold room ceiling is accessible. Before choosing it, check that the ceiling can bear the weight of the unit.

Mounting
On top of the ceiling, with the evaporator inside the cold room
Below the ceiling
The evaporator projects 130 to 160 mm, depending on the size
Cold room temperature
+5 to −2 °C · −18 to −22 °C
Refrigerants
R290 · R455A · CO₂
Condenser
Air-cooled or water-cooled
Power supply
230 V single-phase or 400 V three-phase
Ambient temperature
+16 to +38 °C

Standard equipment

  • Sealed circuit, with hermetic compressor on anti-vibration mounts
  • Automatic hot gas defrost
  • Remote control panel, with manual defrost and alarms
  • Relay for remote alarms
  • High-pressure switch with automatic reset
  • Cold room light and door microswitch cable
  • Filter drier and drain trap
  • Ready for Frigotel supervision

Equipment as listed in the R290 and R455A catalogues. CO₂ Kuma units have a semi-hermetic compressor, an electronic expansion valve and a water-cooled plate condenser.

Models and capacities

The 66 Kuma 50 Hz models, with the cooling capacity and guide room volume given in the CIBIN catalogue. Choose the refrigerant and filter by type of cold room.

Kuma in R290

Propane, a natural refrigerant (GWP 3), with a maximum of 150 g per circuit. 24 models.

Swipe the table to see all the columns →

KUMA models, R290
ModelCold roomCondenserPower supplyCapacity
W
Guide room volume
m³
Sound pressure
dB(A) at 10 m
Footprint and height
mm
Quote
Kuma 05123NChillerAir-cooled230/1/507365.552495 × 900 × 490Request price
Kuma 08125NChillerAir-cooled230/1/5010769.552570 × 1055 × 550Request price
Kuma 12125NChillerAir-cooled230/1/5013641352570 × 1055 × 550Request price
Kuma 14125NChillerAir-cooled230/1/50152315.552570 × 1055 × 550Request price
Kuma 25225NChillerAir-cooled230/1/50220224.555920 × 1260 × 595Request price
Kuma 38225NChillerAir-cooled230/1/50305436.555920 × 1260 × 595Request price
Kuma 67325NChillerAir-cooled400/3/50465260571270 × 1260 × 620Request price
Kuma 05123BFreezerAir-cooled230/1/505764.550495 × 900 × 490Request price
Kuma 08125BFreezerAir-cooled230/1/508768.552570 × 1055 × 550Request price
Kuma 11125BFreezerAir-cooled230/1/5010371152570 × 1055 × 550Request price
Kuma 29225BFreezerAir-cooled230/1/5020772955920 × 1260 × 595Request price
Kuma 50325BFreezerAir-cooled400/3/50321552571270 × 1260 × 620Request price
Kuma 05123N-WChillerWater-cooled230/1/506314.2—495 × 900 × 490Request price
Kuma 08125N-WChillerWater-cooled230/1/508977.1—570 × 1055 × 550Request price
Kuma 12125N-WChillerWater-cooled230/1/50116410.1—570 × 1055 × 550Request price
Kuma 14125N-WChillerWater-cooled230/1/50129311.6—570 × 1055 × 550Request price
Kuma 25225N-WChillerWater-cooled230/1/50181718.1—920 × 1260 × 595Request price
Kuma 38225N-WChillerWater-cooled230/1/50366142.8—920 × 1260 × 595Request price
Kuma 67325N-WChillerWater-cooled400/3/50393946.7—1270 × 1260 × 620Request price
Kuma 05123B-WFreezerWater-cooled230/1/504883.3—495 × 900 × 490Request price
Kuma 08125B-WFreezerWater-cooled230/1/507066—570 × 1055 × 550Request price
Kuma 11125B-WFreezerWater-cooled230/1/508618.1—570 × 1055 × 550Request price
Kuma 29225B-WFreezerWater-cooled230/1/50172122.1—920 × 1260 × 595Request price
Kuma 50325B-WFreezerWater-cooled400/3/50266140.2—1270 × 1260 × 620Request price

Kuma in R455A

New-generation A2L refrigerant (GWP 146). 36 models, with three-phase versions (T).

Swipe the table to see all the columns →

KUMA models, R455A
ModelCold roomCondenserPower supplyCapacity
W
Guide room volume
m³
Sound pressure
dB(A) at 10 m
Footprint and height
mm
Quote
Kuma 04123NChillerAir-cooled230/1/507105.550495 × 900 × 490Request price
Kuma 06123NChillerAir-cooled230/1/50837750495 × 900 × 490Request price
Kuma 07125NChillerAir-cooled230/1/5010851052570 × 1055 × 550Request price
Kuma 09125NChillerAir-cooled230/1/5013481352570 × 1055 × 550Request price
Kuma 18225NChillerAir-cooled230/1/50178818.555920 × 1260 × 595Request price
Kuma 21225NChillerAir-cooled230/1/5019542155920 × 1260 × 595Request price
Kuma 24225NChillerAir-cooled230/1/50234826.555920 × 1260 × 595Request price
Kuma 37325NChillerAir-cooled230/1/50327639.5571270 × 1260 × 620Request price
Kuma 37325N(T)ChillerAir-cooled400/3/50337141571270 × 1260 × 620Request price
Kuma 42325NChillerAir-cooled230/1/50358544571270 × 1260 × 620Request price
Kuma 42325N(T)ChillerAir-cooled400/3/50349142.5571270 × 1260 × 620Request price
Kuma 06125BFreezerAir-cooled230/1/50704652570 × 1055 × 550Request price
Kuma 08125BFreezerAir-cooled230/1/50917952570 × 1055 × 550Request price
Kuma 17225BFreezerAir-cooled230/1/5012801555920 × 1260 × 595Request price
Kuma 17225B(T)FreezerAir-cooled400/3/5012801555920 × 1260 × 595Request price
Kuma 23225BFreezerAir-cooled230/1/5018082455920 × 1260 × 595Request price
Kuma 23225B(T)FreezerAir-cooled400/3/5017702355920 × 1260 × 595Request price
Kuma 32325B(T)FreezerAir-cooled400/3/50235834.5571270 × 1260 × 620Request price
Kuma 04123N-WChillerWater-cooled230/1/507876.5—495 × 900 × 490Request price
Kuma 06123N-WChillerWater-cooled230/1/509418—495 × 900 × 490Request price
Kuma 07125N-WChillerWater-cooled230/1/50135713—570 × 1055 × 550Request price
Kuma 09125N-WChillerWater-cooled230/1/50149415—570 × 1055 × 550Request price
Kuma 18225N-WChillerWater-cooled230/1/50188120—920 × 1260 × 595Request price
Kuma 21225N-WChillerWater-cooled230/1/50213623.5—920 × 1260 × 595Request price
Kuma 24225N-WChillerWater-cooled230/1/50256429.5—920 × 1260 × 595Request price
Kuma 37325N-WChillerWater-cooled230/1/50358244—1270 × 1260 × 620Request price
Kuma 37325N-W(T)ChillerWater-cooled400/3/50360444—1270 × 1260 × 620Request price
Kuma 42325N-WChillerWater-cooled230/1/50393449—1270 × 1260 × 620Request price
Kuma 42325N-W(T)ChillerWater-cooled400/3/50375346.5—1270 × 1260 × 620Request price
Kuma 06125B-WFreezerWater-cooled230/1/507557—570 × 1055 × 550Request price
Kuma 08125B-WFreezerWater-cooled230/1/5098910—570 × 1055 × 550Request price
Kuma 17225B-WFreezerWater-cooled230/1/50141417—920 × 1260 × 595Request price
Kuma 17225B-W(T)FreezerWater-cooled400/3/50142117—920 × 1260 × 595Request price
Kuma 23225B-WFreezerWater-cooled230/1/50198027—920 × 1260 × 595Request price
Kuma 23225B-W(T)FreezerWater-cooled400/3/50195626.5—920 × 1260 × 595Request price
Kuma 32325B-W(T)FreezerWater-cooled400/3/50250837.5—1270 × 1260 × 620Request price

Kuma in CO₂ (R744)

Subcritical cycle, water-cooled, with inlet water at 20 °C maximum. 6 three-phase models.

Swipe the table to see all the columns →

KUMA models, CO₂ (R744)
ModelCold roomPower supplyCapacity
W
Guide room volume
m³
Footprint and height
mm
Quote
Kuma 26225N-SWChiller400/3/50245726.4920 × 1260 × 595Request price
Kuma 39225N-SWChiller400/3/50321636.7920 × 1260 × 595Request price
Kuma 60325N-SWChiller400/3/50434252.41270 × 1260 × 620Request price
Kuma 26225B-SWFreezer400/3/50190525.5920 × 1260 × 595Request price
Kuma 35225B-SWFreezer400/3/50232633.5920 × 1260 × 595Request price
Kuma 85325B-SWFreezer400/3/50431375.81270 × 1260 × 620Request price

Cooling capacity and guide room volume from the CIBIN catalogue, with the cold room at 0 °C for chiller and −20 °C for freezer models, and an ambient temperature of 32 °C. The volume is for a cube-shaped cold room insulated on all sides, with product entering at +15 °C (chiller) or −15 °C (freezer). Dimensions taken from the catalogue drawings, for guidance only: footprint width and length, and overall height.

For other temperatures, the catalogue gives the full table for each model. And for a calculation based on your actual conditions, tell us about your cold room.

Example: Kuma 09125N-W

How to read the model code

The code sums up the unit size, the condenser fans and the type of cold room. It is explained in CIBIN's own catalogue.

09
SizeFrame size of the unit. Not its capacity
1
FansNumber of condenser fans
25
DiameterOf the fan. 25 means Ø254 mm
N
Cold roomN: chiller. B: freezer
-W
WaterWater-cooled. No suffix: air-cooled

In addition, (T) indicates a 400 V three-phase version, and SW the water-cooled subcritical-cycle CO₂ units. The same code may exist in Laika, Kuma and Norca with different capacities: when ordering a unit, always state the series and the refrigerant.

Kuma catalogues

CIBIN's three monoblock catalogues, with the data sheet, drawing and capacity table for each model. Browse them here or download them, no registration needed.

R290 monoblocks

Propane, a natural refrigerant, with a reduced charge, for small and medium-sized cold rooms.

183 pp. · 6.8 MB · IT EN FR DE ES
Download

R455A monoblocks

Laika, Kuma and Norca for normal and low temperature, with A2L refrigerant.

299 pp. · 9.7 MB · IT EN FR DE ES
Download

CO₂ (R744) monoblocks

Water-cooled CO₂, in all three mounting types.

65 pp. · 2.6 MB · IT EN FR DE ES
Download

Kuma: frequently asked questions

How far does it project into the cold room?

According to the catalogue drawings, the evaporator body sits between 130 and 160 mm below the ceiling, depending on the size of the unit. The rest goes on top of the ceiling.

What ambient temperature can it handle?

The pages for each Kuma model state +16 to +38 °C: five degrees less than Laika and Norca, which go up to +43 °C. If the room where the unit is going exceeds 38 °C, ask us before choosing an air-cooled Kuma.

How is it operated?

From a remote control panel: temperature to one decimal place, cold room light, manual defrost and alarms. Options include a version for placing the panel more than 15 m away, and a second, slave panel.

Can two units be fitted in the same cold room?

Yes. As an option, CIBIN offers an electrical panel that manages and alternates two units in the same cold room.

R290, R455A or CO₂?

R290 is propane: a natural refrigerant, GWP 3 and class A3 (flammable), with a maximum of 150 g per circuit. R455A is an A2L blend, mildly flammable, with GWP 146. Both cover chilled and frozen storage, air-cooled or water-cooled.

CO₂ (GWP 1) is only made in water-cooled, three-phase versions, and runs at high pressure: it calls for a contractor trained in CO₂.

CIBIN distributor in Spain and Portugal

Which Kuma does your cold room need?

Tell us the volume, the temperature and where the unit will go, and we'll tell you the model, price and lead time.